Description
The U3400-KEE is a lightweight rooftop attachment system consisting of an U-Anchor 3000 Series plate, flashing cover and separator membrane. The cover and separator membrane are factory sealed to the top of the plate. The U3400-KEE provides a fastened, watertight, warranted attachment for KEE single-ply membranes.
Advantages
• Extremely strong and lightweight.
• Fast installation, approximate rate of 12 per man hour.
• Installs on any surface from flat to vertical.
U-Anchor Attachment
The U3400-KEE is attached by lifting the flashing to expose the fastening holes on the plate. Then, fastening through the roofing assembly and into the structural decking with 2-12 approved fasteners, as directed by project specific engineering. The membrane cover is then hot air welded around the perimeter to the roof membrane. Project-specific data is required to determine the correct type of fastener and number needed to secure each U-Anchor. An ANSI/SPRI FX-1 Pull Test is recommended to measure the pull-out resistance of fasteners included in the load path, (for example,substrate -> fasteners -> the U-Anchor -> other components.)
Equipment Attachment
To securely mount your rooftop equipment to the U-Anchor, after its installed, the connection nut must be tightened to approximately 20-25 ft.-lbs. Use a calibrated torque wrench during install to ensure appropriate
results are achieved. Refer to product documentation for detailed installation and component requirements.
The U3400-KEE is a lightweight rooftop attachment system consisting of an U-Anchor 3000 Series plate, flashing cover and separator membrane. The cover and separator membrane are factory sealed to the top of the plate. The U3400-KEE provides a fastened, watertight, warranted attachment for KEE single-ply membranes.
Advantages
• Extremely strong and lightweight.
• Fast installation, approximate rate of 12 per man hour.
• Installs on any surface from flat to vertical.
U-Anchor Attachment
The U3400-KEE is attached by lifting the flashing to expose the fastening holes on the plate. Then, fastening through the roofing assembly and into the structural decking with 2-12 approved fasteners, as directed by project specific engineering. The membrane cover is then hot air welded around the perimeter to the roof membrane. Project-specific data is required to determine the correct type of fastener and number needed to secure each U-Anchor. An ANSI/SPRI FX-1 Pull Test is recommended to measure the pull-out resistance of fasteners included in the load path, (for example, substrate -> fasteners -> the U-Anchor -> other components.)
Equipment Attachment
To securely mount your rooftop equipment to the U-Anchor, after its installed, the connection nut must be tightened to approximately 20-25 ft.-lbs. Use a calibrated torque wrench during install to ensure appropriate results are achieved. Refer to product documentation for detailed installation and component requirements.
The 3000-S plate is designed for our Snow Retention Solution. With a shorter plate than its sibling, the 3000, the 3000-S also provides the strength of two connection points. The two-bolt plate offers great versatility and customizability depending on your project needs. Snow retention projects are best suited for 3000-S Series.
This anchor only comes in white online.
We also only allow a quantity of 200 of this anchor to be purchases online.
Please contact us if you need more or a different color.
CLICK HERE to contact us for other colors and options